MIL-PRF-15160/1G
REQUIREMENTS:
Interface and physical dimensions: See figure 1.
Terminals: Ferrule type.
Material: Brass, copper, phosphor bronze, or copper alloy.
Finish: Nickel, or silver plated when specified.
Strength: Method 211 of MIL-STD-202, test condition E, 10 inch-ounce torque between ferrules and
fuse body.
Body: Glass tube.
Electrical:
Current rating: See table I.
Voltage rating: See table I.
Characteristic: See table I.
Resistance: See table I.
Overload interrupt: Maximum 1 hour at 135 percent of rated current and a maximum of 5 seconds at
200 percent of rated current.
Short circuit interrupt: See table I.
Shock: 1/100 ampere through 5 ampere; Method 213 of MIL-STD-202, test condition I.
Vibration: 1/100 ampere through 5 amperes; Method 204 of MIL-STD-202, test condition A (except 5g
peak).
Type designation: Type designation shall be as specified in table I.