MIL-PRF-15160/37B
REQUIREMENTS:
Interface and physical dimensions: See figure 1.
Body: Fiber.
Ferrule: Brass.
Terminal strength: 5 inch-pounds.
Type designation: Type designation shall be as specified in table 1.
Electrical:
Voltage rating: 125 volts dc maximum.
Overload interrupt:
Characteristic A: Maximum 1 hour at 135 percent of rated current.
Characteristic B: Maximum 1 hour at 135 percent of rated current, and a minimum of 30 seconds at
300 percent
Short circuit interrupt: 10,000 amperes at 125 volts dc.
Current rating: See table 1.
Voltage rating: See table 1.
Characteristic: See table 1.
TABLE 1. Type designation and electrical rating.
Style
Characteristic
Voltage
Current
F37
A
125 V
20 A
F37
A
125 V
25 A
F37
A
125 V
30 A
F37
B
125 V
20 A
F37
B
125 V
25 A
F37
B
125 V
30 A
VERIFICATION:
Qualification is not applicable for this specification sheet and is replaced by successful completion of group A
and group B inspections in MIL-PRF-15160, before product is delivered.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business