MIL-PRF-15160/60J
TABLE I. Type designation. 1/
Style
Characteristic
Voltage
Current
1/8A
500V
C
F60
2/10A
500V
C
F60
1/4A
500V
C
F60
3/10A
500V
C
F60
3/8A
500V
C
F60
1/2A
500V
C
F60
3/4A
500V
C
F60
1A
500V
C
F60
1 1/2A
500V
C
F60
2A
500V
C
F60
3A
500V
C
F60
4A
500V
C
F60
5A
500V
C
F60
6A
500V
C
F60
8A
500V
C
F60
10A
500V
C
F60
15A
500V
C
F60
20A
500V
C
F60
25A
500V
C
F60
30A
500V
C
F60
1/ For silver plated terminals, the designator "S" is added after
the current rating.
VERIFICATION:
Qualification inspections: The number of qualification samples required shall be:
a. 24 samples maximum current rating of each voltage and design.
b. 24 samples minimum current rating of each voltage and design.
NOTE: If labels are used, five additional samples of any rating are required.
Sample size: The number of group III samples shall be twelve samples each of the maximum and
minimum current ratings. The samples shall be divided as shown in table II.
TABLE II. Short circuit test.
Number of
Short circuit
Test
samples
current
voltage
500 V ac 1/
5,000 A
3
200,000 A
3
500 V ac 1/
5,000 A
3
500 V dc
150,000 A
3
500 V dc
1/ A 600 volt ac test voltage may be used.
Group C inspection: Group C inspection shall be performed on short circuit current ratings of 5,000 A at
500 V ac; 200,000 A at 500 V ac; and 5,000 A at 500 V dc. The 150,000 A at 500 V dc short circuit
current test is not required to be performed for group C testing.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business