MIL-PRF-23419/7J
Verification: The following tests shall be conducted on 100 percent of the units, in the order shown,
prior to any tests referenced in MIL-PRF-23419. Nonconforming units shall be removed from the lot.
Seal: Immerse in a clear mineral oil bath at +125°C for 1 minute. No bubbles shall be detected.
(See method 112 of MIL-STD-202, test condition A.)
Voltage drop: See table I.
Resistance: See table I.
Visual and mechanical: Inspection shall be by 3X minimum magnification.
TABLE I. PIN identification.
PIN
Cold resistance (ohms)
Voltage drop
(volts) 2/
1/
Charac-
Maximum
Current
Style
teristic
voltage
rating
Minimum
Maximum
Minimum
Maximum
(volts)
(amperes)
FM07
A
125V
1/500A
1,750
2,250
3.56
5.34
FM07
A
125V
1/200A
245
315
1.74
2.60
FM07
A
125V
1/100A
82.2
106
1.28
1.92
FM07
A
125V
1/64A
38.5
49.5
.864
1.30
FM07
A
125V
1/32A
14.4
18.5
.680
1.02
FM07
A
125V
1/20A
2.82
3.58
.168
.247
FM07
A
125V
1/16A
1.98
2.52
.148
.222
FM07
A
125V
1/10A
1.03
1.31
.130
.194
FM07
A
125V
1/8A
.880
1.12
.151
.225
FM07
A
125V
2/10A
2.03
2.57
.400
.600
FM07
A
125V
1/4A
1.54
1.96
.368
.552
FM07
A
125V
3/10A
1.10
1.40
.320
.480
FM07
A
125V
4/10A
.193
.261
.123
.184
FM07
A
125V
1/2A
.142
.192
.110
.160
FM07
A
125V
6/10A
.119
.161
.114
.171
FM07
A
125V
7/10A
.097
.131
.105
.157
FM07
A
125V
3/4A
.088
.120
.101
.151
FM07
A
125V
8/10A
.080
.108
.101
.153
FM07
A
125V
1A
.088
.112
.106
.158
FM07
A
125V
1-1/2A
.0555
.0705
.113
.169
FM07
A
125V
2A
.0405
.0515
.098
.146
FM07
A
125V
3A
.0299
.0381
.106
.162
FM07
A
125V
4A
.0167
.0213
.080
.120
FM07
A
125V
5A
.0159
.0201
.106
.160
1/ Cold resistance is measured at 10 percent or less of rated current.
2/ Voltage drop is measured after the fuse has been subjected to rated current for not less than one
minute.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business