MIL-PRF-23419/9D
TABLE I. PIN designation and electrical ratings - Continued.
PIN designation
Overload interrupt time 1/
AC short circuit
Cold resistance 2/
135 % of rating, maximum
interrupt
(ohms)
1 hour
Style
Charac-
Maximum
Current
200% of
300 % of
125 volts
250 volts
Minimum
Maximum
teristic
voltage
rating
rating
rating
(amperes)
(seconds)
(seconds)
FM09
B
250 V
1/100A
4.0-250.0
2.0-40.0
10,000A
35 A
950.0
4620.0
FM09
B
250 V
1/32 A
4.0-80.0
2.0-25.0
10,000A
35 A
100.0
462.0
FM09
B
250 V
1/16 A
4.0-80.0
2.0-25.0
10,000A
35 A
49.0
120.0
FM09
B
250 V
1/10 A
4.0-80.0
2.0-25.0
10,000A
35 A
14.0
17.5
FM09
B
250 V
1/8 A
4.0-80.0
2.0-25.0
10,000A
35 A
9.0
11.0
FM09
B
250 V
15/100 A
4.0-80.0
2.0-25.0
10,000A
35 A
6.9
8.0
FM09
B
250 V
3/16 A
4.0-80.0
2.0-25.0
10,000A
35 A
4.0
5.5
FM09
B
250 V
1/4 A
4.0-80.0
2.0-25.0
10,000A
35 A
3.18
10.5
FM09
B
250 V
3/10 A
4.0-80.0
2.0-25.0
10,000A
35 A
2.22
7.10
FM09
B
250 V
3/8 A
4.0-80.0
2.0-25.0
10,000A
35 A
1.5
4.77
FM09
B
250 V
1/2 A
4.0-80.0
2.0-25.0
10,000A
35 A
1.2
2.83
FM09
B
250 V
6/10 A
4.0-80.0
2.0-25.0
10,000A
35 A
.60
2.10
FM09
B
250 V
3/4 A
4.0-80.0
2.0-25.0
10,000A
35 A
.45
1.43
FM09
B
250 V
8/10 A
4.0-80.0
2.0-25.0
10,000A
35 A
.35
1.26
FM09
B
250 V
1A
4.0-80.0
2.0-25.0
10,000A
35 A
.21
.64
FM09
B
250 V
1-1/4 A
4.0-80.0
2.0-25.0
10,000A
35 A
.16
.38
FM09
B
250 V
1-1/2 A
4.0-80.0
2.0-25.0
10,000A
35 A
.102
.340
FM09
B
250 V
1-6/10 A
4.0-80.0
2.0-25.0
10,000A
35 A
.099
.270
FM09
B
250 V
2A
4.0-80.0
2.0-25.0
10,000A
35 A
.072
.180
FM09
B
250 V
2-1/2 A
10.0-250.0
2.0-25.0
10,000A
35 A
.052
.154
FM09
B
250 V
2-8/10 A
10.0-250.0
2.0-25.0
10,000A
35 A
.032
.090
FM09
B
250 V
3A
10.0-250.0
2.0-25.0
10,000A
35 A
.026
.090
FM09
B
250 V
3-2/10 A
10.0-250.0
2.0-25.0
10,000A
35 A
.025
.090
FM09
B
125 V
4A
10.0-250.0
2.0-25.0
10,000A
Not rated
.0240
.0560
FM09
B
125 V
5A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0108
.0600
FM09
B
125 V
6-1/4 A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0071
.0450
FM09
B
125 V
7A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0059
.0300
FM09
B
125 V
8A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0070
.0200
FM09
B
125 V
10 A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0056
.0140
FM09
B
125 V
12 A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0036
.0110
FM09
B
125 V
15 A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0017
.0080
FM09
B
125 V
20 A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0012
.0040
FM09
B
125 V
25 A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0009
.0030
FM09
B
125 V
30 A
10.0-250.0
0.05-10.0
10,000A
Not rated
.0006
.0022
1/ The overload interrupt time ranges, as shown, cover the temperature range from -55°C to +85°C. For
characteristic B, the overload interrupt time at room ambient temperature shall be 12 seconds minimum at 200
percent of rating.
2/ Cold resistance is measured at 10 percent or less of rated current.
3/ Add "S" suffix to the end of the PIN designation if optional silver plating is required.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business