MIL-PRF-15160/9G
TABLE I Part or Identifying Number and electrical ratings - Continued.
PIN
AC short circuit interrupt.
Style
Characteristic
Maximum
Current
voltage
rating 2/
32 volts
125 volts
250 volts
(amperes)
F09
1/
B
250V
5 6/10A
10,000A
10,000A
100A
F09
B
250V
6 1/4A
10,000A
10,000A
100A
F09
1/
B
250V
7A
10,000A
10,000A
100A
F09
B
250V
8A
10,000A
10,000A
100A
F09
1/
B
250V
9A
10,000A
10,000A
100A
F09
B
250V
10A
10,000A
10,000A
100A
F09
1/
B
125V
12A
10,000A
10,000A
Not rated
F09
B
125V
15A
10,000A
10,000A
Not rated
F09
B
32V
20A
10,000A
Not rated
Not rated
F09
B
32V
25A
10,000A
Not rated
Not rated
F09
B
32V
30A
10,000A
Not rated
Not rated
1/ INACTIVE FOR NEW DESIGN AFTER 30 JANUARY 1970.
2/ For silver plated terminals the designator "S" is added after the current rating.
INSPECTION ROUTINE:
Short circuit interrupt: The number of group III samples for qualification and qualification retention
(group C) testing shall consist of 4 sample fuses of each of the types and of the current ratings as
shown in table II. Short circuit interrupt tests shall be conducted at the ac voltage indicated, and the
fuses shall withstand a minimum short circuit current as shown in table II.
TABLE II. Short circuit tests.
Fuse type
Current rating
Short circuit
AC test
current
voltage
F09A
4A
35A
250V
F09A
10A
100A
250V
F09A
20A
200A
250V
F09A
30A
750A
250V
F09A
30A
10,000A
125V
F09B
4A
35A
250V
F09B
10A
100A
250V
F09B
15A
10,000A
125V
F09B
30A
10,000A
32V
Cross-reference: For applicable cross-reference see table III. The existing stocks of superseded
items may be used. When exhausted, the superseding parts shall be used.