MIL-PRF-23419/2R
TABLE I. PIN designation identification.
PIN designation
Short circuit interrupt rating
Maximum
Current rating
(amperes ac) 1/
Voltage
(amperes)
Style
Characteristic
(volts)
FM02
A
125V
1/500 A
10,000
FM02
A
125V
1/200 A
10,000
FM02
A
125V
1/100 A
10,000
FM02
A
125V
1/64 A
10,000
FM02
A
125V
1/32 A
10,000
FM02
A
125V
1/16 A
10,000
FM02
A
125V
1/10 A
10,000
FM02
A
125V
1/8 A
10,000
FM02
A
125V
2/10 A
10,000
FM02
A
125V
1/4 A
10,000
FM02
A
125V
3/10 A
10,000
FM02
A
125V
4/10 A
10,000
FM02
A
125V
1/2 A
10,000
FM02
A
125V
6/10 A
10,000
FM02
A
125V
3/4 A
10,000
FM02
A
125V
1A
10,000
FM02
A
125V
1-1/2 A
10,000
FM02
A
125V
2A
10,000
FM02
A
125V
3A
300
FM02
A
125V
4A
300
FM02
A
125V
5A
300
1/ AC short circuit test current may be applied at a random point on the voltage sine wave.
Qualification and group C inspection:
Inspection routine. The number of group II samples for qualification, and subgroup 2 samples for
group C inspection, shall be as shown in table II:
TABLE II. Group II and subgroup 2 samples.
Inspection
Number of sample fuses
Group II and subgroup 2
16
Terminal strength
4
Overload interrupt
200 percent at -55°C
4
200 percent at +85°C
4
300 percent at -55°C
4
300 percent at +85°C
4