MIL-DTL-24646/11B
REQUIREMENTS
Symbol numbers: See table I.
Design:
Electrical rating: 125 volts alternating current, 0-10 ampere, 60 hertz.
Dimensions and configuration: See figures 1, 2, 3, 4, 5 and 6.
Wiring diagrams: See figure 7.
Mounting dimensions: See figure 3.
Degree of enclosure: Watertight (3 feet).
Nonmagnetic enclosure: Nonmagnetic enclosures shall be brass in accordance with
MIL-E-24142. Attaching hardware shall be nonmagnetic and shall have a
magnetic permeability not greater than 2.0.
Designation and marking: See MIL-DTL-24646.
Parts: The parts listed in table II and specified in MIL-DTL-24646 shall be used in the construction of
the fuse boxes specified herein.
General information:
Military part numbers and general information are as specified in table I.
TABLE I. Military part numbers and general information.
Supersedes
Bus bar
Fuse
Branch
Feeder
No. of
Weight
Symbol
Military
size
size
MCM
MCM
circuits
in
no.
part no.
Type
Drawing
pounds
no.
M24646/11-
645
26.8
4
14
4
midget
0.62 x 0.12
9-S-74196
18-A
001
0-30A
M24646/11-
645.1
26.8
4
14
4
midget
0.62 x 0.12
9-S-74196
18-B
002
0-30A
M24646/11-
649.1
28.2
4
14
4
midget
0.62 x 0.12
9-S-74197
D-12A
003
0-30A
M24646/11-
650.1
36.2
8
14
4
midget
0.62 x 0.12
9-S-74201
22-A
004
0-30A